DIMENSION Q-SERIES | 3-PHASE DIN RAIL POWER SUPPLIES

Article Number Approvals DC Output Range Power Input Dimension WxHxD (mm) Special Feature Datasheet Download
QT20.241 1, 2, 3, 4, 5, 7, 8, 11, 12, 13 24V 20A 24-28Vdc 480W AC 380-480V 65 124 127 -
⚫ 3AC 380-480V Wide-range Input
⚫ Extra Long Lifetime
⚫ 95% Full Load and Excellent Partial Load Efficiencies
⚫ Width only 65mm, Weight only 870g
⚫ 50% BonusPower ® , 720W for up to 4s
⚫ Active Power Factor Correction PFC
⚫ Active Filtering of Input Transients
⚫ Full Power Between -25°C and +60°C
⚫ Extremely Low Input Inrush Current Surge
⚫ DC-OK Relay Contact
⚫ Quick-connect Spring-clamp Terminals
QT20.241-C1 1, 2, 3, 4, 5, 7, 8, 11, 12, 13, 15 24V 20A 24-28Vdc 480W AC 380-480V 65 124 127 conformal coated
⚫ 3AC 380-480V Wide-range Input
⚫ Extra Long Lifetime
⚫ 95% Full Load and Excellent Partial Load Efficiencies
⚫ Width only 65mm, Weight only 870g
⚫ 50% BonusPower ® , 720W for up to 4s
⚫ Active Power Factor Correction PFC
⚫ Active Filtering of Input Transients
⚫ Full Power Between -25°C and +60°C
⚫ Extremely Low Input Inrush Current Surge
⚫ DC-OK Relay Contact
⚫ Quick-connect Spring-clamp Terminal
⚫ EN 50155 approved for railway applications
QT20.361 1, 2, 3, 4, 5, 7, 8, 11, 13 36V 13.3A 36-42Vdc 480W AC 380-480V 65 124 127 -
⚫ 3AC 380-480V Wide-range Input
⚫ Also Specified for 2-Phase Operation
⚫ 94.8% Full Load and Excellent Partial Load Efficiencies
⚫ Width only 65mm, Weight only 870g
⚫ 50% BonusPower ® , 720W for up to 4s
⚫ Active Power Factor Correction PFC
⚫ Active Filtering of Input Transients
⚫ Full Power Between -25°C and +60°C
⚫ Extremely Low Input Inrush Current Surge
⚫ DC-OK Relay Contact
⚫ Quick-connect Spring-clamp Terminals
QT20.481 1, 2, 3, 4, 5, 7, 8, 11, 13 48V 10A 48-55Vdc 480W AC 380-480V 65 124 127
⚫ 3AC 380-480V Wide-range Input
⚫ Also Specified for 2-Phase Operation
⚫ 95.4% Full Load and Excellent Partial Load Efficiencies
⚫ Width only 65mm, Weight only 870g
⚫ 50% BonusPower ® , 720W for up to 4s
⚫ Active Power Factor Correction PFC
⚫ Active Filtering of Input Transients
⚫ Full Power Between -25°C and +60°C
⚫ Extremely Low Input Inrush Current Surge
⚫ DC-OK Relay Contact
⚫ Quick-connect Spring-clamp Terminals
QT40.241 1, 2, 3, 4, 5, 7, 8, 9, 11, 12, 13 24V 40A 24-28Vdc 960W AC 380-480V 110 124 127 -
⚫ 380-480V Wide-range input and active PFC
⚫ Efficiency up to 95,3%
⚫ Negligibly low input inrush current
⚫ 50% Power reserves available up to 4s
⚫ Full output power between -25°C and +60°C
⚫ DC-OK Contact; Shut-down Input
QT40.242 1, 2, 3, 4, 7, 8, 9 24V 40A 24-28Vdc 960W AC 380-480V 110 124 127 extra long lifetime
⚫ Extra longlife version of QT40.241
⚫ Efficiency up to 95,3%
⚫ Negligibly low input inrush current
⚫ 50% Power reserves available up to 4s
⚫ Full output power between -25°C and +60°C
⚫ DC-OK Contact; Shut-down Input
QT40.361 1, 2, 3, 4, 8, 9 36V 26.7A 36-42Vdc 960W AC 380-480V 110 124 127 -
⚫ 380-480V Wide-range input and active PFC
⚫ Efficiency up to 95,3%
⚫ Negligibly low input inrush current
⚫ 50% Power reserves available up to 4s
⚫ Full output power between -25 and +60°C
⚫ DC-OK Contact; Shut-down Input
QT40.481 1, 2, 3, 4, 5, 6, 7, 8, 9, 13 48V 20A 48-54Vdc 960W AC 380-480V 110 124 127 -
⚫ 380-480V Wide-range input and active PFC
⚫ Efficiency up to 95,4%
⚫ Negligibly low input inrush current
⚫ 50% Power reserves available up to 4s
⚫ Full output power between -25 and +60°C
⚫ DC-OK Contact; Shut-down Input